- For grouting wall and floor tiles
- Exposed to high mechanical load and impact
- For car wash installations, industrial kitchens, and swimming pools
- For interior and exterior use
- Joint widths from 2 mm to 18 mm
- Excellent workability
- High mechanical strength
- Improved resistance to chemicals
- Tolerates high-pressure cleaning
Products
-
-
PlaneMix S40Pool and concrete repair mortar
-
PlaneMix 80Fast-track screeding mortar
-
PlaneMix 80 cementRapid setting cement for screeds
-
PlaneMix 100Fast-setting screeding mortar
-
PlaneMix 100 cementFast-setting screeding mortar
-
PlaneMixPrimerPrimer for Alfix PlaneMix levelling compounds
-
PlaneMixBinderAdmix for Planemix levelling compounds
-
-
-
TopCoat DesignUltra matt topcoat for levelled industrial looking floors
-
PlaneMix S8 rapidStand firm universal filler
-
PlaneMix 10Self-levelling and smoothing compound
-
PlaneMix S12 rapidSlump-free smoothing and repair mortar
-
PlaneMix 20Self-levelling and smoothing compound
-
PlaneMix 25 exteriorSelf-levelling and smoothing compound. Interior and exterior use
-
PlaneMix 30Self-levelling and smoothing compound
-
PlaneMix 50Self-levelling compound
-
PlaneMix 50 less dustDust reduced self-levelling compound
-
PlaneMix 60Self-levelling fibre-reinforced smoothing compound
-
PlaneMixPrimerPrimer for Alfix PlaneMix levelling compounds
-
PlaneMixBinderAdmix for Planemix levelling compounds
-
UniversalPrimerImproves adhesion in preparation for Alfix levelling compounds and tile adhesives on dense, non-absorbent substrates. Rollable consistency
-
Accessories for Alfix PlaneMix
-
-
-
ProFix PlusFlexible dust reduced tile adhesive
- Up to 1200 x 1200 mm -
ProFixFlexible tile adhesive - Light
-
LetFix less dustFlexible dust reduced tile adhesive - Light
-
LetFixFlexible tile adhesive - Light
-
LetFix UniversalFlexible tile adhesive - Light
-
CombiQuickFixRapid setting flexible tile adhesive
-
QuickFix premiumRapid-setting natural stone adhesive
-
FlexFixRapid-setting flexible natural stone adhesive
-
CombiFixFlexible tile adhesive
-
NormalFixTile adhesive
-
FlexBinder
-
UniversalPrimerImproves adhesion in preparation for Alfix levelling compounds and tile adhesives on dense, non-absorbent substrates. Rollable consistency
-
ReadyFlexReady mixed tile adhesive
-
C2 EpoxyAcid-resistant grout and tile adhesive
-
Thixotropic agentAdditive for Alfix C2 Epoxy
-
Montagelim1-component all-round mounting adhesive
-
-
-
FineFuge - CeraFill 5Fine grout
-
QuickFuge - Premium 8Rapid-setting natural stone grout
-
UniversalFuge - CeraFill 10Universal grout
-
IndustryFuge - CeraFill 18High-strength grout
-
RustiqFuge - CeraFill 20Wide joint grout
-
M-SiliconHighly elastic sealant
-
C2 EpoxyAcid-resistant grout and tile adhesive
-
Thixotropic agentAdditive for Alfix C2 Epoxy
-
EpoxyFuge 10252-component flexible, epoxy-based pool grout
-
Montagelim1-component all-round mounting adhesive
-
-
-
DuraPuds 615Water repellent plinth render
-
DuraPuds 650 rapidRapid-hardening repair and levelling render
-
DuraPuds 703Through coloured thin coat finishing mortar
-
DuraPuds 710Thin coat bonding mortar
-
DuraPuds 804Flexible, through-coloured thin coat finishing mortar
-
DuraPuds 810Flexible fibre render
-
DuraPuds 830Flexible facade adhesive - Light
-
DuraPuds 800 SRSilicone resin-based facade render
-
DuraDec 8000 SRSilicone resin-based facade paint
-
Accessories for DuraPuds
-
IndustryFuge - CeraFill 18
Product information
Product
Cement-based powder containing polymer modifiers. Added special fillers. Contains quartz sand with grain sizes up to 0.4 mm.
Coverage
0.8 - 1.6 kg per m² depending on tile size and joint width.
Packaging
Available in 20 kg PE lined paper bags
Technical data
- Working temperature
- +5°C - +30°C
- Density
- 2.0 kg/litre (mixed with water)
- Working time
- 1 - 2 hours at +20°C
- Foot traffic
- After 24 hours at +20°C
- Full strength
- After 14 days at +20°C
- High pressure cleaning
- Max. 100 bar
- Classification - DS/EN 13888
- CG 2, high class
- Shelf life
- Min. 12 months in unopened bags
General information
For car wash installations, industrial kitchens, and swimming pools.
Grouting can usually be made 48 hours after tiling has been completed. Joints should be clean, dry, free from dust and loose particles from adhesive and bedding mortar Joint depth should appear uniform.
For grouting of certain types of receptive tiles, such as matt glazed or porous tiles, stains and excess grout can be very difficult to remove. In case of doubt, it is recommendable to do a trial application on a limited and less visible area to ascertain resistance.
Underfloor heating, ventilation, waste heat recovery systems, dehumidifiers, etc should be switched off during tiling. Deactivate all installations 72 hours prior to grouting and reactivate 14 days after completion of work at the earliest. Underfloor heating temperature increase should be by 5°C per 24 hours until preferred surface temperature is obtained.
Inlet temperature should be max. +35°C
Colours
Available in Manhattan - steel grey.
Application
How to use
Add 0.17 – 0.19 litre clean, cold water per kg powder. Pour the water into a clean container and add the powder while stirring thoroughly with mixing drill. Keep stirring until the consistency is completely uniform, smooth, and lump-free. Allow the mixture to rest for a few minutes and stir briefly before use.
Apply Alfix IndustryFuge grout to the surface with a soft rubber squeegee while working diagonally over the joints ensuring that they are compacted and completely filled. Remove excess grout immediately while working.
When the grout begins to set, within 15-30 minutes, slurry off the area using wet sponge frequently rinsed in clean water. Wipe over tiles in broad, diagonal sweeps until joints appear even and filled. Finally, clean off and finish tiles and joints with only slightly damp sponge.
Note!
Premature cleaning with wet sponge or the exposure to varying site conditions, such as heat, draught or ventilation, may affect the natural properties of the cement and cause discolouration or damage to the grouted joint.
Avoid acid washing if possible. If grout film has to be removed from the surface, pre-water the joints before acid washing.
To ensure complete hardening and strength development, it is important to keep the joints moist for the first 4-5 days.
Note that the temperature of mixing water will influence setting time. Higher room and water temperature will shorten time.
Protect the joints from heat, draught, and other climatic conditions which will affect drying.
Do not cover areas just grouted with plastic foil or sheets, and avoid leaving small pools of water in the joints during the first 3-4 days.
Cleaning
Remove residues of Alfix IndustryFuge - CeraFill 18 from tiles and tools with water before the mix begins to set.
Cement-based products harden when mixed with water, hence do not pour surplus grout into the drainage system.